Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Chinese Journal of Traumatology ; (6): 131-138, 2023.
Article in English | WPRIM | ID: wpr-981930

ABSTRACT

PURPOSE@#SAM junctional tourniquet (SJT) has been applied to control junctional hemorrhage. However, there is limited information about its safety and efficacy when applied in the axilla. This study aims to investigate the effect of SJT on respiration when used in the axilla in a swine model.@*METHODS@#Eighteen male Yorkshire swines, aged 6-month-old and weighing 55 - 72 kg, were randomized into 3 groups, with 6 in each. An axillary hemorrhage model was established by cutting a 2 mm transverse incision in the axillary artery. Hemorrhagic shock was induced by exsanguinating through the left carotid artery to achieve a controlled volume reduction of 30% of total blood volume. Vascular blocking bands were used to temporarily control axillary hemorrhage before SJT was applied. In Group I, the swine spontaneously breathed, while SJT was applied for 2 h with a pressure of 210 mmHg. In Group II, the swine were mechanically ventilated, and SJT was applied for the same duration and pressure as Group I. In Group III, the swine spontaneously breathed, but the axillary hemorrhage was controlled using vascular blocking bands without SJT compression. The amount of free blood loss was calculated in the axillary wound during the 2 h of hemostasis by SJT application or vascular blocking bands. After then, a temporary vascular shunt was performed in the 3 groups to achieve resuscitation. Pathophysiologic state of each swine was monitored for 1 h with an infusion of 400 mL of autologous whole blood and 500 mL of lactated ringer solution. Tb and T0 represent the time points before and immediate after the 30% volume-controlled hemorrhagic shock, respectively. T30, T60, T90 and T120, denote 30, 60, 90, and 120 min after T0 (hemostasis period), while T150, and T180 denote 150 and 180 min after T0 (resuscitation period). The mean arterial pressure and heart rate were monitored through the right carotid artery catheter. Blood samples were collected at each time point for the analysis of blood gas, complete cell count, serum chemistry, standard coagulation tests, etc., and thromboelastography was conducted subsequently. Movement of the left hemidiaphragm was measured by ultrasonography at Tb and T0 to assess respiration. Data were presented as mean ± standard deviation and analyzed using repeated measures of two-way analysis of variance with pairwise comparisons adjusted using the Bonferroni method. All statistical analyses were processed using GraphPad Prism software.@*RESULTS@#Compared to Tb, a statistically significant increase in the left hemidiaphragm movement at T0 was observed in Groups I and II (both p < 0.001). In Group III, the left hemidiaphragm movement remained unchanged (p = 0.660). Compared to Group I, mechanical ventilation in Group II significantly alleviated the effect of SJT application on the left hemidiaphragm movement (p < 0.001). Blood pressure and heart rate rapidly increased at T0 in all three groups. Respiratory arrest suddenly occurred in Group I after T120, which required immediate manual respiratory assistance. PaO2 in Group I decreased significantly at T120, accompanied by an increase in PaCO2 (both p < 0.001 vs. Groups II and III). Other biochemical metabolic changes were similar among groups. However, in all 3 groups, lactate and potassium increased immediately after 1 min of resuscitation concurrent with a drop in pH. The swine in Group I exhibited the most severe hyperkalemia and metabolic acidosis. The coagulation function test did not show statistically significant differences among three groups at any time point. However, D-dimer levels showed a more than 16-fold increase from T120 to T180 in all groups.@*CONCLUSION@#In the swine model, SJT is effective in controlling axillary hemorrhage during both spontaneous breathing and mechanical ventilation. Mechanical ventilation is found to alleviate the restrictive effect of SJT on thoracic movement without affecting hemostatic efficiency. Therefore, mechanical ventilation could be necessary before SJT removal.


Subject(s)
Male , Animals , Swine , Shock, Hemorrhagic/therapy , Tourniquets , Axilla , Hemorrhage/therapy , Vascular Diseases , Respiration
2.
World Journal of Emergency Medicine ; (4): 297-300, 2022.
Article in English | WPRIM | ID: wpr-929651
3.
Chinese Journal of Traumatology ; (6): 125-131, 2021.
Article in English | WPRIM | ID: wpr-879690

ABSTRACT

With the widespread adoption of advanced tourniquets, the mortality rate of limb wound hemorrhage has decreased significantly, and non-compressible torso hemorrhage has gradually occupied the leading position of potentially preventable death, both in military and civilian circumstances. With the emergence of novel hemostatic devices and materials, strategies for the management of non-compressible torso hemorrhage have changed significantly. This review summarizes the current treatment strategies and types of equipment for non-compressible torso hemorrhage and suggests future research directions, hoping to provide a comprehensive review for the medical personnel and researchers engaging in this field.

4.
Military Medical Sciences ; (12): 707-710, 2017.
Article in Chinese | WPRIM | ID: wpr-665691

ABSTRACT

Objective To provide reference for the cold chain of stored RBCs on the sea by evaluating both blood containers containing phase-changed materials and the quality of stored RBCs during transportation.Methods In order to simulate blood supply on the sea,we transported the stored RBCs on land(100 min),on the sea(45 h)and stored them on the sea for another 7 days.The free hemoglobin(Hb), lactate dehydrogenase(LDH), and concentrations of K +and Na+were measured.Results The temperature of the blood container containing phase-changed materials rose from 4.1℃to 9.5℃.The contents of free Hb,K+and LDH were increased to(0.083 ±0.032)g/L,(15.097 ±1.791)mmol/L, and(106.00 ±17.83)U/L,respectively.During blood storage,the contents of the above three indices were increased to (0.111 ±0.035)g/L,(27.238 ±3.509)mmol/L and(227.00 ±111.94)U/L, while Na +decreased to(113.63 ± 4.012)mmol/L.Conclusion The temperature of the blood container containing phase-changed materials can be maintained at a constant temperature under more complicated environmental conditions,and the quality of the stored RBCs can be ensured.RBCs stored on the sea for more than 7 days are damaged more seriously than those stored on land.

5.
Military Medical Sciences ; (12): 758-761, 2017.
Article in Chinese | WPRIM | ID: wpr-665679

ABSTRACT

Objective To assess the limit of detection(LOD),sensitivity and specificity of collodial gold immunochrom-atography(GICA)products purchased from two manufacturers under special environmental conditions.Methods The sensitivity and specificity of GICA made in InTec Products, INC.and Beijing WANTAI Biological Pharmacy Enterprise Co., LTD.for detecting HBsAg, anti-HCV and anti-Treponema pallidum(TP)serum samples were evaluated under different conditions(conventional facilities,simulated hot and humid environments and simulated low pressure and hypoxia environments)according to the protocol of kits.LOD was estimated by detecting the standard materials obtained from the National Center for Clinical Laboratory(NCCL)of China.Results LOD for syphilis improved from 2 NCU to 1 NCU using GICA from InTec Products in hot and humid environments.The extreme conditions did not influence the specificity of GICA from the two manufacturers in the course of detection of clinical samples,but the sensitivity of detection was affected.For InTec Products,the sensitivity of hepatitis B virus and syphilis detection was improved in hot and humid environments,but was reduced in low pressure and hypoxia environments.In addition,the sensitivity of hepatitis C virus detection by InTec Products decreased in hot and humid environments.As for WANTAI products,the sensitivity of hepatitis B virus detection was reduced under extreme conditions and that of hepatitis C virus was only influenced by hot and humid environments. Interestingly, extreme conditions had no impact on the sensitivity of syphilis.Conclusion LOD of InTec Products is better than that of the WANTAI products for detection of standard materials from blood-borne diseases.In the process of detecting clinical samples,the sensitivity of the two manufacturers′GICA is influenced by extreme conditions, with the specificity unchanged.Overall, WANTAI products are more stable than those of InTec, and are also less influenced by extreme conditions.

6.
Chinese Journal of Traumatology ; (6): 352-356, 2015.
Article in English | WPRIM | ID: wpr-316784

ABSTRACT

<p><b>PURPOSE</b>To investigate the prevalence and diagnosis rate of intra-abdominal hypertension (IAH) in a mixed-population intensive care unit (ICU), and to investigate the knowledge of ICU staff regarding the guidelines published by the World Society of Abdominal Compartment Syndrome (WSACS) in 2013.</p><p><b>METHODS</b>A one-day cross-sectional study based on the WSACS 2013 guidelines was conducted in the general ICU of a tertiary teaching hospital in Chongqing, China. The included patients were divided into intravesical pressure (IVP) measured group and IVP unmeasured group. The epidemiologic data were recorded, and potential IAH risk factors (RFs) were collected based on the guidelines. IVP measurements were conducted by investigators every 4 h and the result was compared to that measured by the ICU staff to evaluate the diagnosis rate. Besides, a questionnaire was used to investigate the understanding of the guidelines among ICU staff.</p><p><b>RESULTS</b>Thirty-two patients were included, 14 in the IVP measured group and 18 in the IVP unmeasured group. The prevalence of IAH during the survey was 15.63% (5/32), 35.71% (5/14) in IVP measured group. Only one case of IAH had been diagnosed by the ICU physician and the diagnosis rate was as low as 20.00%. Logistic regression analysis showed that sequential organ failure assessment (SOFA) score was an independent RF for IAH (OR: 1.532, 95% CI: 1.029-2.282, p=0.036. Fourteen doctors and 5 nurses were investigated and the response rate was 67.86%. The average scores of the doctors and nurses were 27.14±20.16 and 16.00±8.94 respectively. None of them had studied the WSACS 2013 guidelines thoroughly.</p><p><b>CONCLUSION</b>Patients with a higher SOFA score has a higher incidence of IAH. The IAH prevalence in 14 ICU patients with indwelling catheter was 35.71%. Strengthening the wide and rational use of WSACS guideline is important to improve the diagnosis of IAH.</p>


Subject(s)
Aged , Female , Humans , Male , Middle Aged , China , Epidemiology , Critical Illness , Epidemiology , Cross-Sectional Studies , Intensive Care Units , Intra-Abdominal Hypertension , Diagnosis , Epidemiology , Prevalence , Risk Factors , Severity of Illness Index , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL